CM-184
INDUSTRIAL PROGRAMMABLE CONTROLLER
A Industrial PLC Training System
Featuring The Allen Bradley SLC 500 Controller
The CM-184 is a complete Industrial-based PLC training system featuring the Allen-Bradley
SLC500, a rapidly growing family of compact, but powerful, programmable
controllers.
Allen Bradley SLC500 Specifications
Processor: 5/01 CPU (standard), 5/02 (option)
CURRICULUM
Training begins with a fully illustrated computer-based interactive course
which introduces the basics of ladder logic and details the SLC 500 family of
PLCs. An in-depth explanation of SLC 500 addressing is followed by an
animated explanation of programming instructions. Upon completion of
practice activities, the trainee challenges his/her newly acquired skills by
taking a scored test. All trainee activities are recorded for the
instructor's record. The CBT course allows flexible access and is fully
indexed for later use as reference material.
Once familiar with programming techniques, the trainee goes on-line with the
SLC 500 using TII's Advanced Control System Laboratory Manual. Activities
include writing and running a wide range of PLC programs for industrial
applications. Keystroke Reference Cards are provided for the programming
software and hand-held terminal.
SPECIFICATIONS
The CM-184-C Computer Based Training includes:
The Laboratory Manual includes:
Return to Advanced Technology Training
About TII | Our
Products | Our Customers |
New Products
Brochures
| Useful Links | Contact
Us | Comments
TII Technical Education Systems
Program Memory: 1K (standard), 4M (option)
I/O Capacity: 44 standard (expandable to 432)
I/O Types: AC and DC standard (Analog and User
Selectable available as options)
Racks or Slots: Seven slot racks (expandable to 3 racks,
10 slots each)
Standard RAM Memory: Capacitor Battery (2 years)
Back-up or Life: Optional Lithium Battery (5 years)
Memory Back-up Options: EEPROM or UVPROM
LED Indicators: Run, CPU, Fault, Forced I/O, Battery Low
Programming: APS or HHT
Typical Scan Time: 8 ms/K
Bit Execution (XIC): 4 microseconds
Communication: DH-485 receive
a) Manager's Guide for classroom management
b) Five Quick Reference Guides
c) One Serial Mouse (for CBT Interface)
d) Five CBT Modules, including:
Hardware required for the above CBT module includes:
- IBM PC 286 (or compatible)
- One floppy drive & hard disk
- One parallel port
- EGA (640 X 350) graphics
a) Pre-Test for easy placement of trainees in course
b) Three Keystroke Reference Cards
c) Five Laboratory Modules including:
800/451-2169 (toll-free within the U.S.)
847/566-7400 (for international customers)
847/566-7474 (fax)
404 Washington Blvd
Mundelein, IL 60060
USA